Air Conditioning Tips: How to Troubleshoot a Failed AC Unit

Monday, April 30th, 2012

In most cases, an air conditioners in need of maintenance may be fixed by going through some troubleshooting guidelines. If you would like one of our Cave Creek air conditioning technicians to help you get your AC unit running again, give Cool Touch for assistance. We can also send someone to your home if we can’t get your system working again.

Here are some basic steps to try before you call for a repair.

Check All Controls and Fuses

When your air conditioner won’t cool your home properly, always check the thermostat to see if it is on “cool” and set for the right temperature. If the air conditioner has shut down, check to make sure that the unit is receiving power by looking in the fuse box for a flipped circuit breaker and also making sure it is plugged in properly. You can also inspect the visible wires and electrical components for obvious damages. Call a Cave Creek air conditioning technician if you see physical damage to the electrical components. Never try to fix this yourself.

Sometimes when there’s extreme weather conditions in the summer, such as very high temperatures or high humidity levels, the high-pressure switch can get flipped and turn off the air conditioner. You can easily find the switch on most AC models in the compressor’s access panel. Check your owner’s manual or call us if you don’t know how to locate or reset the limit switch.

Check for Refrigerant Problems or Condensate Pan Leaks

Refrigerant problems caused by the wrong amount of refrigerant can keep the AC unit from cooling your home properly, and you can usually tell if there’s a refrigerant issue by looking for frost or icing on the evaporator coil. When there’s excess coil icing, it means that there isn’t enough cool air being delivered to your home. If you see thick frost on the evaporator coil, a technician will most likely need to charge the refrigerant, or there could be a leak in the refrigerant line.

Condensate leaks into the condensate pan can also cause an air conditioner to fail. The condensate drip pan is installed underneath the air handler to catch condensate leaks if the drain system gets clogged. Most of the time, a small clog in the drain line can be easily cleared. Also check the condensate switch for issues; sometimes these can be defective and cause your air conditioner to shut down.

At Cool Touch, we want to be the only Cave Creek air conditioning contractor you’ll ever need. Call Cool Touch any time to get troubleshooting advice for your AC system.

Continue Reading

Indoor Air Conditioning Components for Peoria Homes

Monday, April 16th, 2012

Air conditioning in Peoria is a modern convenience that we can easily take for granted as long as all the parts are working well.  In every unit, no matter the size, the basic process is one of extracting heat from the conditioned space and moving it to the outside, leaving cool air in its place.

This process easily divides into indoor and outdoor components.

Air Conditioning 101

Based on the principal of thermal energy which states that heat gravitates toward cooler temperatures, compounds known as refrigerants are moved through a closed loop system, repeatedly contracting and expanding between liquid and gas forms, alternately releasing and absorbing heat along the way.  The particular chemicals are selected for their abilities to transform from one state to the other at low temperatures.

While the refrigerant evaporates into a gaseous state within the looped system, it absorbs heat, removing the stale air from the space being conditioned and evacuating it to the outdoors. The warm air is pulled through ducts to meet with the cooling loop.

Ductwork

The cooled air is distributed through ducts or tubing and released into individual spaces.  Additional ductwork is required to remove the stale air and pull it back to be reconditioned as it passes over the loop containing the refrigerant.  The air is moved in both directions by a blower, usually electric and sized to handle the amount of air no matter the building.

Ductwork is also sized to handle appropriate volumes of air. To maintain efficiency, large trunks distribute along central lines to smaller ones reaching farther out. The return air is usually taken from common areas.

The grates are found in the walls, floors and often as part of the dropped ceiling. When combined with a forced air heating system, the total energy use is much more efficient.

Looped Coils

The refrigerant is enclosed in a loop where it can expand and contract to make its transformation from gas to liquid and back again.  To change into a heat-absorbing gas, it travels through the evaporating coils, an intricate series of delicate fins that meets with the ductwork to regenerate the conditioned air.

An exchange valve allows just the right amount of liquid refrigerant into the evaporator coils.  If there is too much, the tube is flooded too tightly to allow expansion of the molecules and room to attract the heat.  If too little, the process is inefficient.

Cool Maintenance

If an air conditioning maintenance is performed on a regular basis, the system functions with little attention and over sight.  Relaxed and comfortable, even on the most brutal of days, we are able to do our stuff and sleep well.  Contact Cool Touch Air Conditioning & Heating Specialists

Continue Reading